791-798
Analysis of the Comparison of TPW Realizations in Europe in Light of CCT Recommendation 2 (CI-2005)
E. Renaot, M. H. Valin and M. Elgourdou
799-807
Implementing a New Group of TPW Cells as National Standard: Impact on Calibration Services
Miruna Dobre
808-814
Open AccessIsotopic Composition of Water Used in Triple-Point Cells
K. S. Gam, K. H. Kang, Y.-G. Kim and I. Yang
815-824
The Long-Term Drift of Triple-Point-of-Water Cells
X. K. Yan, C. F. Ma, Z. Zhang, H. L. Wu and P. Qiu, et al.
825-835
Realization of the Triple Point of Water in Metallic Sealed Cells at the LNE-INM/CNAM: A Progress Report
F. Sparasci, L. Pitre and Y. Hermier
836-843
Method for Compensating Heat Flux Errors in Mini-TPW Cell Measurements
M. Heinonen and E. Isosaari
844-851
Mechanism to Diminish the Supercooling of the Tin Freezing Point by using Graphite Powder
Jin Tao Zhang and Y. N. Wang
852-860
Influence of Impurities and Filling Protocol on the Aluminum Fixed Point
E. Renaot, M. H. Valin and M. Elgourdou
861-870
Development of Fixed-Point Cells at the SMU
S. Ďuriš, J. Ranostaj and R. Palenčár
871-880
Components of a Variance Model for the Analysis of Repeated Measurements in Fixed-Point Comparisons
Eduarda Filipe
881-889
Comparison System for the Calibration of Capsule-Type Standard Platinum Resistance Thermometers at NMIJ/AIST
T. Nakano, O. Tamura and H. Sakurai
890-901
SPRT Calibration Uncertainties and Internal Quality Control at a Commercial SPRT Calibration Facility
T. J. Wiandt
902-914
Uncertainty Evaluation and Validation of a Comparison Methodology to Perform In-house Calibration of Platinum Resistance Thermometers using a Monte Carlo Method
A. Silva Ribeiro, J. Alves e Sousa, C. Oliveira Costa, M. Pimenta Castro and M. G. Cox
915-925
Inhomogeneity Measurements of Long Thermocouples using a Short Movable Heating Zone
Magnus Holmsten, Jan Ivarsson, Roland Falk, Mats Lidbeck and Lars-Erik Josefson
926-934
Metal–Carbon Eutectics to Extend the Use of the Fixed-Point Technique in Precision IR Thermometry
M. Battuello, F. Girard and M. Florio
935-943
Experimental Investigation of the Cr3C2–C Peritectic Fixed Point
W. Zheng, Y. Yamada and Y. Wang
944-957
Investigation of TiC–C Eutectic and WC–C Peritectic High-Temperature Fixed Points
Naohiko Sasajima and Yoshiro Yamada
958-968
Investigation of Impurity Elimination Effect in Metal–Carbon Alloys
A. Burdakin, M. Sakharov, B. Khlevnoy, S. Ogarev and V. Sapritsky, et al.
969-983
Springer-Verlag
Large- and Small-Aperture Fixed-Point Cells of Cu, Pt–C, and Re–C
Klaus Anhalt, Yunfen Wang, Yoshiro Yamada and Jürgen Hartmann
984-990
Realization of the Temperature Scale in the Range from 234.3 K (Hg Triple Point) to 1084.62°C (Cu Freezing Point) in Croatia
Davor Zvizdic, Tomislav Veliki and Lovorka Grgec Bermanec
991-1000
Intercomparison of the Realizations of the ITS-90 from 83.8058 K to 692.677 K among European NMIs
E. Renaot, Y. Hermier, M. H. Valin, G. Bonnier and F. Adunka, et al.
1001-1013
ITS-90 Scale Realization on the New Radiation Thermometer Calibration Facility at NMi VSL
P. R. Dekker and E. W. M. van der Ham
1014-1025
Middle Temperature Scale for Infrared Radiation Thermometer Calibrated Against Multiple Fixed Points
Y. Shimizu and J. Ishii
1026-1040
NIST Radiance Temperature and Infrared Spectral Radiance Scales at Near-Ambient Temperatures
S. N. Mekhontsev, V. B. Khromchenko and L. M. Hanssen
1041-1051
AC-Mode Short-Wavelength IR Radiation Thermometers for Measurement of Ambient Temperatures
G. P. Eppeldauer and H. W. Yoon
1052-1065
Radiation Thermometry Toward the Triple Point of Water?
Jürgen Hartmann and Lutz Werner
1066-1083
Uncertainty Budgets for Calibration of Radiation Thermometers below the Silver Point
P. Saunders, J. Fischer, M. Sadli, M. Battuello and C. W. Park, et al.
1084-1093
Filter Radiometers as a Tool for Quality Assurance of Temperature Measurements with Linear Pyrometers
M. Ojanen, V. Ahtee, M. Noorma, T. Weckström and P. Kärhä, et al.
1094-1106
Development of a Multiband near-to-far Infrared Radiance COmparator (MIRCO)
J. Joly, P. Ridoux, J. Hameury, M. Lièvre and J.-R. Filtz
1107-1115
Long-Term Stability of 0.65-μm Radiation Thermometers at NMIJ
Fumihiro Sakuma and Laina Ma
1116-1122
Peak-Wavelength Method for Temperature Measurement
Jingmin Dai, Xinbei Wang and Xiaodong Liu
1123-1130
In-Field-of-View Thermal Image Calibration System for Medical Thermography Applications
R. C. Simpson, H. C. McEvoy, G. Machin, K. Howell and M. Naeem, et al.
1131-1140
An Alternative Calculation of the Size-of-Source Effect Uncertainty for Non-uniform Sources
M. J. Martín, J. P. Pérez and V. Chimenti
1141-1155
Analysis of the Accuracy of Methods for the Direct Measurement of Emissivity
Raúl B. Pérez-Sáez, Leire del Campo and Manuel J. Tello
1156-1165
Thermal Noise Sensor Insulation Using Ultra-thin Ceramic Coatings
O. Kerkhof, E. Houtzager, J. v. Wensveen and E. Maloney
1166-1173
Rapid-Response Hybrid-Type Surface-Temperature Sensor
K. Hiraka, R. Shinagawa, A. Gogami and T. Iuchi
1174-1183
Uncertainty of the Calibration of Paired Temperature Sensors for Heat Meters
Erich Tegeler, Dieter Heyer and Bernd. R. L. Siebert
1184-1192
Simulation of Thermal Behavior in High-Precision Measurement Instruments
Hanna Sophie Weis and Silke Augustin
1193-1203
CCT WG8 CMC Review Protocols: Development and Implementation
G. F. Strouse, M. Ballico, J. Bojkovski, M. de Groot and H. G. Liedberg, et al.