Open reduction and internal fixation is the treatment of choice in distal humerus fractures. The aims of the treatment are
to obtain anatomic reconstruction and restoration of the elbow’s geometry followed by stable internal fixation that allows
immediate rehabilitation. The plates are pre-contoured to fit the natural anatomy of the elbow and in the case of complex
fractures they provide a guide for the anatomic restoration of the distal humerus. The two plates are placed parallel with
the screws locked together by interdigitation creating a fixed angle in the distal fragments that provides stability to the
entire distal humerus. Using this method we obtained good results according to the Mayo Elbow Performance Score (MEPS) and
we are able to reduce the incidence of complications. Our experience shows also that it can be useful to obtain an anatomical
reduction of distal humeral fractures using the pre-contoured plates in a parallel position recovering the anatomical antiversion
of the articular surface.
Keywords Pre-contour plate - Mayo elbow congruent plates - Elbow fracture - Anatomical reduction - Stable fixation - Early motion