Background: The qualities of visual perception and of motor reaction to the visual stimulus have never been studied in reference to the
type of video-camera system (2-D vs 3-D) used during laparoscopy.
Methods: The study was designed in two parts. The first evaluated the ability of the eye to discriminate how objects are spaced relative
to one another. The second investigated the motor reaction to the visual stimulus in an environment where depth was the preponderent
cue. The tests were performed in a pelvi-trainer in which were inserted different modules built either for visual observation
(Part 1) or for evaluation of motor ability (Part 2). Variables studied during Part 1 were the time required to do the test
and the number of errors committed during its performance. The variable evaluated during Part 2 was the time needed to terminate
the test. Each of these two parts of the study were completed alternating the 2-D and 3-D systems. A total of 304 observations
were recorded. Statistics used were the paired t-test, the independent group t-test, and the Newman-Keuls multiple comparisons test.
Results: Results of Part 1 of the study confirm that visual perception varies significantly among individuals (n = 10) (p < 0.05) and that a true 3-D video-camera system facilitates visual perception when compared to a 2-D system (p < 0.001). Results of Part 2 of the study also show significant differences among participants (n= 9) (p < 0.05). The true 3-D system allowed significantly faster motor performances than the 2-D system (p < 0.001).
Conclusion: Our experiment shows that the 3-D system allowed significant improvements in the execution of the evaluated parameters. Also
noted were significant differences among participants in term of visual and motor skills.
Key words: Laparoscopy — In vitro tests — three-dimensional videocamera system — Monocularity — Binocularity