Volume 129, Number 3, 353-358, DOI: 10.1007/s00402-008-0681-z

Published in partnership with the

Logo

German Speaking Arthroscopy Association

Rotational instability of the knee: internal tibial rotation under a simulated pivot shift test

Nadine Diermann, Tobias Schumacher, Steffen Schanz, Michael J. Raschke, Wolf Petersen and Thore Zantop

View Related Documents

Abstract

Introduction  

Recently, several publications investigated the rotational instability of the human knee joint under pivot shift examinations and reported the internal tibial rotation as measurement for instrumented knee laxity measurements. We hypothesize that ACL deficiency leads to increased internal tibial rotation under a simulated pivot shift test. Furthermore, it was hypothesized that anatomic single bundle ACL reconstruction significantly reduces the internal tibial rotation under a simulated pivot shift test when compared to the ACL-deficient knee.

Methods  

In seven human cadaveric knees, the kinematics of the intact knee, ACL-deficient knee, and anatomic single bundle ACL reconstructed knee were determined in response to a 134 N anterior tibial load and a combined rotatory load of 10 N m valgus and 4 N m internal tibial rotation using a robotic/UFS testing system. Statistical analyses were performed using a two-way ANOVA test.

Results  

Single bundle ACL reconstruction reduced the anterior tibial translation under a simulated KT-1000 test significantly compared to the ACL-deficient knee (P < 0.05). After reconstruction, there was a statistical significant difference to the intact knee at 30° of knee flexion. Under a simulated pivot shift test, anatomic single bundle ACL reconstruction could restore the intact knee kinematics. Internal tibial rotation under a simulated pivot shift showed no significant difference in the ACL-intact, ACL-deficient and ACL-reconstructed knee.

Conclusion  

In conclusion, ACL deficiency does not increase the internal tibial rotation under a simulated pivot shift test. For objective measurements of the rotational instability of the knee using instrumented knee laxity devices under pivot shift mechanisms, the anterior tibial translation should be rather evaluated than the internal tibial rotation.

Keywords  Single bundle - ACL reconstruction - Revision - Rotational instability - Robotic/UFS testing system

This study was supported in part by a grant of the German Speaking Association of Arthroscopy (AGA).

Fulltext Preview

Image of the first page of the fulltext document