Background
No consensus exists regarding the optimal treatment of ipsilateral femoral neck and shaft fractures. The three major issues
related to these fractures are the optimal timing of surgery, which fracture to stabilize first, and the optimal implant to
use. In an effort to find answers to these three key issues, we report our experience of managing 27 patients with ipsilateral
femoral neck and shaft fractures by using two different treatment methods, i.e., reconstruction-type intramedullary nailing
and various plate combinations.
Materials and methods
We divided patients into two groups. Group I included 15 patients (13 males and 2 females) who were operated with cancellous
lag screws or dynamic hip screws (DHS) for fractured neck and compression plate fixation for fractured shaft of the femur.
Group II included 12 patients (11 males and 1 female) who were operated with reconstruction-type intramedullary nailing.
Results
Mean age was 33.2 and 37.9 years in group I and II, respectively. Mean delay in surgery was 5.9 and 5.4 days in group I and
II, respectively. Average union time for femoral neck fracture in groups I and II were 15.2 and 17.1 weeks, respectively;
and for shaft fracture these times were 20.3 and 22.8 weeks, respectively. There were 13 (86.6%) good, 1 (6.7%) fair and 1
(6.7%) poor functional results in group I. There were 10 (83.3%) good, 1 (8.3%) fair and 1 (8.3%) poor functional results
in group II.
Conclusions
Both of the treatment methods used in the present study achieved satisfactory functional outcome in these complex fractures.
Fixation with plate for shaft and screws or DHS for hip is easy from a technical point of view. Choice of the treatment method
should be dictated primarily by the type of femoral neck fracture and the surgeon’s familiarity with the treatment method
chosen. The femoral neck fracture should preferably be stabilized first, and a delay of 5–6 days does not affect the ultimate
functional outcome.
Keywords Reconstruction nailing - Plating - Ipsilateral femoral neck and shaft fracture - Dynamic hip screw - Lag screw