When THA is required in a patient with developmental dysplasia of the hip (DDH), bone deficiency in the acetabular roof often precludes conventional methods of socket implantation. Options for obtaining adequate bone coverage for stable fixation of the acetabular component have included use of a small cup with medial or high anatomic positioning of the socket [19, 23]. Augmented bone graft prepared from resected femoral head to the defective acetabulum is another option [2, 6, 7, 24–27, 29]. Bulk bone grafting offers advantages: the cup may be placed in an anatomic position rather than a high one, it provides support for the acetabular component, and if incorporated it would provide beneficial bone stock for any future revision surgery. Although the importance of coverage and initial stability of the socket is accepted as a principle, numerous authors have reported high rates of autograft resorption, collapse of the bone graft, and socket loosening [7, 8, 10, 12, 21, 22, 28, 31]. Mulroy and Harris [22] reported failure of 46% of their cemented series by 11.8 years. In comparison to the failure rate reported by Mulroy and Harris [22], survival of 94% at 6.6 years was reported by Morsi et al. [21] although they also reported mild or moderate resorption of 69% of their 16 cementless series. Spangehl et al. reported a survival rate of 91% at 10 years using a cementless acetabular component [31].
Numerous studies have examined the use of uncemented THA with femoral head autografts to augment socket coverage with bone [1, 9, 10, 13, 21, 28, 30, 31]. Shetty et al. [28] described 15 hips with acetabular dysplasia treated with uncemented THA in conjunction with bulk autografts from femoral heads with no cases of loosening or revision at 8 to 11 years. Ito et al. [13] described 15 dysplastic hips treated with uncemented cups combined with femoral head bone grafting and reported six of the 15 cups had a mean vertical migration of 4.5 mm within 5 years after surgery. In that study, however, serial radiographs did not show any progression of migration or rotation of the socket after 5 years at least up to a mean followup of 10.6 years. Hendrich and Mehling [9] reported 55 uncemented cups with bone grafting in patients followed a mean of 10 years and substantial socket migration was observed in 19 hips. In some of these studies, the authors obtained initial mechanical strength by using the eburnated superior portion of femoral head [28] or a portion of femoral head that includes the calcar [12]. We believe the variations in survival suggest technique may be important in the survival of the cups. Hemispheric porous sockets and greater surface contact between bone grafts and living host bone should reduce the early interfacial stresses on the graft and stresses between the graft and host bed and thus enhance the chance of survival. There also may be differing rates of survival with cemented and uncemented sockets placed on bulk autografts.
Using particular techniques to implant the graft and socket, we therefore determined (1) the 10-year survival rate with loosening, (2) coverage of the acetabular component by host bone, (3) chronologic radiographic changes in grafted bone during repair of acetabular bone deficiency in dysplastic hips, (4) leg lengthening achieved by the autografts, and (5) functional outcomes.
|
Characteristic |
Value |
|---|---|
|
Age (years)* |
57 (33–72) |
|
Height (cm)* |
152 (137–165) |
|
Weight (kg)* |
54 (36–78) |
|
Gender (male/female) |
2/68 |
|
Crowe type (number of hips) |
|
|
I |
10 |
|
II |
45 |
|
III |
19 |
|
IV |
9 |
All patients were allowed to stand and walk with two crutches and nonweightbearing within 2 days after surgery. All received ROM exercise by physiotherapy until 3 weeks, and began walking exercises with partial weightbearing (50% of normal weightbearing) with crutches during 3 to 6 weeks, followed by gradual return to full weightbearing. Patients were permitted to return to work 2 months postoperatively.
We followed patients at 2, 4, 6, 9, and 12 months after surgery, and every 6 or 12 months thereafter. We obtained the Merle d’Aubigné and Postel hip score [20] at 12 months and yearly thereafter. Measurement of leg length was evaluated by comparing the position of the midportion of the lesser trochanter to the interteardrop line on preoperative and postoperative radiographs. We defined a high hip center as one with the center greater than 35 mm proximal to the interteardrop line.
Incorporation and remodeling of grafted bone were analyzed according to the methods described by Knight et al. [15]. Bridging trabeculation across the graft-host interface was judged to be present when the interface apparent on early radiographs could no longer be seen distinctly. Rounding off of the protruding edge of the graft beyond the cup or a change in graft density in areas where the graft was not stressed was considered an indicator of revascularization. Reorientation of the trabecular pattern in the graft to match the normal trabecular orientation of the acetabular dome also was noted. Vertical and horizontal positions of the acetabular socket were determined according to the methods described by Russotti and Harris [27]. Radiolucent lines at the acetabular bone-implant interface were recorded as described by DeLee and Charnley [5]. Inclination angle of the socket was determined as the angle subtended by the face of the socket and the interteardrop line on AP radiographs. Probable or definite acetabular loosening was defined as a change in socket position, socket migration, screw fracture, or complete radiolucency at the bone-implant interface of 2 mm or greater in any zone. Linear head penetration into the polyethylene liner was measured using the techniques described by Livermore et al. [17].
For patients who subsequently underwent revision during followup, clinical and radiographic data just before revision surgeries were used for analysis. Kaplan-Meier survival analysis [14] was used to calculate the probability of retention of the original prosthesis with 95% confidence intervals. The Kruskal-Wallis test was used to determine differences in coverage of the acetabular component by bone (CE, CE II, CE III), horizontal coverage above the socket, and bone graft staging as defined by Knight et al. [15] to dislocation type as defined by Crowe et al. [4]. We used StatView® software (SAS Institute Inc, Cary, NC) for all analyses.
The 10-year survival rate without acetabular revision for any reason (wear, osteolysis, loosening) was 94% (95% confidence interval, 92%–96%). The 10-year survival rate with loosening was 97% (95% confidence interval, 95%–99%). Although we observed no patients with socket loosening attributable to collapse of the autograft, we did revise five hips during followup. Four hip prostheses were revised at 6.5, 7, 8.1, and 13 years after the index procedure owing to severe polyethylene wear and periprosthetic osteolysis. In all of these patients, the cup was firmly fixed to the acetabulum at the time of revision. One patient had revision surgery at 9 years because of acetabular loosening. No radiolucent lines were apparent at the graft-implant interface at the last followup in 65 of the 77 cups (84%), but thin (< 1-mm) radiolucent lines at the socket-graft interface without socket loosening were seen in 12 hips. The mean rate of head penetration into the polyethylene liner was 0.10 mm/year (range, 0–0.38 mm/year). Pelvic osteolytic lesions were observed adjacent to the acetabular component in eight hips. Femoral osteolytic lesions without loosening were observed in five hips with high wear rates.
|
Parameter |
Value |
|---|---|
|
Socket inclination (°)* |
44 (32–60) |
|
Hip center (mm) |
|
|
Horizontal* |
30.4 (20–39) |
|
Vertical* |
23.7 (13–37) |
|
Graft coverage |
|
|
Horizontal coverage (%)* |
45 (23–66) |
|
Center-edge angle (°)* |
−3.4 (−20–15) |
|
Radiolucent lines in DeLee and Charnley zones (number of hips) |
|
|
I |
13 (12%) |
|
II |
3 (3%) |
|
III |
7 (8%) |
|
Crowe et al. type |
Number of hips |
Socket size (mm) |
Horizontal coverage (%)† |
|
|---|---|---|---|---|
|
Immediately postoperatively |
Final followup |
|||
|
I |
10 |
46.8 (46–48) |
59.2 (41–74) |
99 (94–100) |
|
II |
45 |
46.8 (46–48) |
54.7 (34–69) |
100 |
|
III |
19 |
46.1 (46–48) |
55.4 (35–69) |
100 |
|
IV |
9 |
43.3 (42–46) |
61.4 (44–77) |
98 (89–100) |
|
p value |
0.0001 |
0.12 |
0.73 |
|
|
Crowe et al. type |
Number of hips |
CE (°)* |
CE II (°)* |
CE III (°)* |
|---|---|---|---|---|
|
I |
10 |
−2.5 (−20–15) |
48.9 (42–63) |
46.3 (42–63) |
|
II |
45 |
−4.0 (−20–10) |
50.1 (35–65) |
49.0 (35–65) |
|
III |
19 |
−4.4 (−25–10) |
51.3 (40–60) |
48.9 (40–60) |
|
IV |
9 |
2.2 (−15–20) |
48.3 (35–60) |
46.7 (35–60) |
|
P value |
0.37 |
0.88 |
0.82 |
|
Crowe et al. type |
Number of hips |
Knight et al. staging (months)* |
||
|---|---|---|---|---|
|
Trabecular bridging |
Remodeling |
Reorientation |
||
|
I |
10 |
3 (2–6) |
7 (3–18) |
14 (9.6–24) |
|
II |
45 |
3 (2–6) |
8 (3–18) |
19 (12–36) |
|
III |
19 |
3 (2–6) |
8 (3–18) |
17 (12–36) |
|
IV |
9 |
3 (2–6) |
9 (3–18) |
24 (19.2–36) |
|
P value |
0.81 |
0.52 |
< 0.003 |
|
At the last followup, 60 of the 77 hips (78%) were completely incorporated (Fig. 6E), six (8%) had residual bone graft shadow (Fig. 4C), and 11 (14%) had partial sclerosis (Fig. 5C).
Leg length was increased by 24.6 mm (range, 10–65 mm) after surgery owing to the socket setting to the original acetabular cavity and distal shift of the femur.
In cases of acetabular dysplasia, deficient acetabula often provide inadequate coverage of the acetabular socket during THA. Bulk autogenous graft from the femoral head has been used to achieve better coverage, but the long-term benefits of this technique remain controversial. The major concerns with the surgical method of socket setting in the original acetabulum and augmentation with bone grafts to defective iliac bone are loosening of the socket caused by compromised mechanical strength of the graft during the process of incorporation and remodeling of graft bone and subsequent increases in the revision rate [7, 16, 22]. The use of bulk autograft thus remains controversial. We therefore determined (1) the 10-year survival rate with loosening, (2) coverage of the acetabular component by host bone, (3) chronologic radiographic changes in grafted bone during repair of acetabular bone deficiency in dysplastic hips, (4) leg lengthening achieved by the autografts, and (5) functional outcomes.
Our study has several limitations. First, we used only standard AP radiographs, reflecting 2-D images of the hips. As coverage of the socket by host and graft bone is 3-D, we could not capture the 3-D coverage (ie, AP). Second, we could not assess the rate or extent of invasion by reparative tissue into grafted bone and the metabolic condition of the bone in and around the autograft owing to a lack of data obtained by MRI, bone scintigraphy, and bone biopsy of grafts. However, during long-term followup, we observed reduced or absent radiodensity of the original floor of the pseudoacetabulum, reorientation of trabeculae in the graft, and generation of radiodense bands in the graft or along the outer surface of the graft original iliac outer wall to the lateral edge of the socket surface. Serial radiographs showed the appearance of lateral radiodense bands, representing a new outer cortical shell of the ilium and appearing to reflect a final event for successful incorporation of the bulk autograft; we observed no additional morphologic changes after the appearance of these lateral radiodense bands. Thus, there is considerable radiographic evidence of ultimate incorporation although we cannot establish the rate of incorporation. The lateral part of the acetabular roof plays an important role in load transfer. We thus presume large bone grafts have a functional role in load transfer. Third, we had only one observer for the radiographic images. Many of these measures (eg, repair, radiolucent lines, linear measures) are subject to interobserver variability and we have no data regarding the reliability of these measures in our patients. In particular, the data for repair times reflect only estimates. However, the observations regarding long-term repair would not likely be so subject to interobserver variability and these data would not affect the data for survival and revisions.
Based on their experience, Mulroy and Harris [22] advised against bulk autograft fabricated from the femoral head for dysplastic hips owing to a high rate of postoperative resorption and collapse of the bone graft. Based on these clinical experiences, some surgeons have recommended medial or high setting of the noncemented socket without bone grafting and have reported no clear loosening at an average of 10.6 years followup despite a medial or high shift of the anatomic hip center [13]. However, considering future potential loosening of the acetabular sockets in association with periprosthetic bone loss, revision surgery to restore hip function would become much more difficult in these patients owing to limited bone stock. To avoid such potential risks in revision THA, restoration of the acetabular bone defect in primary THA for the dysplastic hip in combination with socket setting in the original acetabulum to restore biomechanically favorable hip function would be desirable. Despite concerns regarding high rates of resorption and collapse, we observed no patient with graft collapse or progressive migration of the socket over 10 years’ followup. Twelve of the 77 hips had periprosthetic radiolucent lines without graft collapse. We presume these were related to polyethylene wear from the conventional polyethylene liners and the use of microstructured sockets. These sockets may have experienced deformation of the liner with increased backside wear as described by Yamaguchi et al. [33]. We speculate the survival relates to the surgical techniques of bone grafting used in this series of cases. Tight fixation of the graft by these techniques would be particularly important in cases requiring a large graft where the mechanical load inevitably would be transmitted to the graft in the postoperative phase owing to increased socket coverage area by the grafted bone. With the improved porous surface, the socket adhered tightly to living host bone. Consequently, early mechanical load on the graft was reduced. Additional factors might contribute to satisfactory incorporation of grafts, but we could not elucidate these using radiographic data alone.
No clear consensus was reached regarding how much of the acetabular component can safely be covered by graft. Mulroy and Harris [22] found grafts covering less than 40% tended to collapse. As a result, they recommended at least 70% coverage of the acetabular component by host bone to give stability and allow adequate ingrowth on bone [22]. Initial socket stability should be achieved to the extent possible with host bone. Some authors believe surgeons should avoid dependence of achieving stability with greater than 60% of the grafted bone [26]. We found the mean percent coverage of the acetabular component by the bulk autograft was 45% (range, 23%–66%). We believe it is important to decrease the stress on the grafted bone. Although many of the bone grafts we used were relatively bulky, we obtained satisfactory results.
Iida et al. [11] reported delayed trabecular reorientation as a risk factor for socket loosening. They used a cemented socket with trabecular reorientation in 89% at an average of 32.5 months. The grafting method described by Knight et al. [15] also involved a cemented socket with either allograft or autograft, resulting in trabecular reorientation in 72% at an average of 16 months. Our grafting technique and cementless socket fixation achieved earlier trabecular reorientation at an average of 24 months.
Leg lengthening greater than 4 cm generally is accepted as a risk factor for nerve injury or palsy. Our THA method for DDH resulted in a mean postoperative lengthening of 24.6 mm. No irreversible nerve damage was identified. In this study, we considered less than 4 cm a desirable level of lengthening for our patients with a mean height of 152 cm.
The mean Merle d’Aubigné and Postel hip score improved from 9.1 preoperatively to 17.2 at last followup. Functional score improvements with medial and high settings of the noncemented socket in THA without bone grafting are similar [13]. Mallory et al. [18] reported frequent dislocation after THA in patients with DDH. The dislocation rate of 11% in the study by Ito et al. [13] with an acceptable high center was greater than our dislocation rate of 2.6%. Silber and Engh [30] reported the potential for hip instability attributable to femoral-pelvic impingement was greater in patients with a high hip center. Intraoperative soft tissue tension was increased adequately by leg lengthening in our patients. An intraoperative check of the dislocation range showed very stable results, which might have been the reason for the low dislocation rate.
An uncemented THA augmented with a femoral head autograft offers a way to ensure anatomic placement of the socket in the AP projection if the THA and bone-grafting procedures are performed carefully. Repair of the deficient acetabulum by the autograft appeared to be complete within 3 years after surgery as judged radiographically. We speculate the high rate of graft incorporation and survival relates to key technical factors: (1) initial stability of the graft and cup; (2) impacted cancellous surfaces of the host and graft to facilitate long-term incorporation and remodeling; and (3) a porous surface of the largest possible sockets to ensure bone ingrowth.








