Measurements were made to determine the coefficient of heat transfer between a vertical cylindrical surface and a fluidization bed with eight different kinds of fixed packing. The data for the maximum heat transfer coefficient have been generalized into design formulas.
Translated from Inzhenerno-Fizicheskii Zhurnal, Vol. 25, No. 1, pp. 50–55, July, 1973.