The Electronic Armament Centre (CELAR: Centre ďElectronique de I’Armement) has evaluated the use of a relatively low frequency
ultra-wide band short pulse measurement facility to characterize target electromagnetic signatures. Specific measurement instrumentation
has been developed and implemented. The initial measurement trial began at the beginning of 1998 and led to the establishment
of a database on various targets. These measurements made it possible to interpret, in the lime domain, the signatures and
to work out holograms. Images were calculated either in the time or the frequency domain.