Introduction
Hemodynamics is thought to play a very important role in the initiation, growth, and rupture of intracranial aneurysms. The
purpose of our study was to compare hemodynamics of intracranial aneurysms of MR fluid dynamics (MRFD) using 3D cine PC MR
imaging (4D-Flow) at 1.5 T and MR-based computational fluid dynamics (CFD).
Methods
4D-Flow was performed for five intracranial aneurysms by a 1.5 T MR scanner. 3D TOF MR angiography was performed for geometric
information. The blood flow in the aneurysms was modeled using CFD simulation based on the finite element method. We used
MR angiographic data as the vascular models and MR flow information as boundary conditions in CFD. 3D velocity vector fields,
3D streamlines, shearing velocity maps, wall shear stress (WSS) distribution maps and oscillatory shear index (OSI) distribution
maps were obtained by MRFD and CFD and were compared.
Results
There was a moderate to high degree of correlation in 3D velocity vector fields and a low to moderate degree of correlation
in WSS of aneurysms between MRFD and CFD using regression analysis. The patterns of 3D streamlines were similar between MRFD
and CFD. The small and rotating shearing velocities and higher OSI were observed at the top of the spiral flow in the aneurysms.
The pattern and location of shearing velocity in MRFD and CFD were similar. The location of high oscillatory shear index obtained
by MRFD was near to that obtained by CFD.
Conclusion
MRFD and CFD of intracranial aneurysms correlated fairly well.
Keywords Intracranial aneurysm - Hemodynamics - Cine phase-contrast MR imaging - Magnetic resonance fluid dynamics - Computational fluid dynamics