Published in partnership with the

Logo

Club Jules Gonin

Outflow mechanisms after deep sclerectomy with two different designs of collagen implant in an animal model

Christophe Nguyen, Radu Christian Boldea, Sylvain Roy, Tarek Shaarawy, Sylvie Uffer and André Mermoud

View Related Documents

Abstract

Background  

To study experimentally two different shapes of collagen implants (CI) used in deep sclerectomy (DS). The ability to promote drainage vessels, outflow mechanisms, success rates, and biodegradability, were studied prospectively in an animal model.

Materials and methods  

DS was performed in 20 eyes of ten rabbits. Each rabbit randomly received a cylindrical CI in one eye, while the other eye received a flat CI. Intraocular pressure (IOP) measurement, ultrasound biomicroscopy (UBM) examination of DS site and simultaneous fluorescein and indocyanin green anterior-segment angiography were performed preoperatively, at 1 and 2 weeks, 1, 2, 3, 6 and 9 months for each eye. At the end of the follow-up period, outflow facility (OF) was measured and histological examinations of the filtration site were performed.

Results  

In the cylindrical implant group, IOP significantly dropped from a mean preoperative value of 14.8±2.2 mmHg to a mean postoperative values of 10.9±3.3, 12.5±2.2, 11.8±2.6, 11.2±2.3, 10.7±1.9, 14.0± 3.2, 12.6±2.4 mmHg at 1, 2 weeks, and 1, 2, 3, 6, and 9 months, respectively. In the flat CI group, IOP significantly dropped from a mean preoperative value of 14.1±1.8 mmHg to a mean postoperative values of 10.4±2.7, 12.7±1.9, 12.5±3.2, 11.2±1.6, 11.6±1.8, 11.5±2.3, 11.0±2.2 mmHg at 1, 2 weeks, and at 1, 2, 3, 6, and 9 months, respectively. UBM images showed a gradual resorption of both type of CI during the first 3 months, and angiographies showed progressive growth of drainage vessels around the filtration site in both groups. The mean OF 9 months postoperatively for the cylindrical CI was 0.53 (SD ± 0.23) ml/min per mmHg and was 0.56 (SD±0.17) ml/min per mmHg for the flat CI (P=0.6). Histological examination revealed excellent biocompatibilty and a high density of drainage vessels in the sclera around the operative site in both groups.

Conclusion  

Using IOP and OF measurements, UBM, angiography, and histology, we were able to compare two types of CI used as space maintainer in DS. Both CIs showed efficient IOP lowering effect and outflow facility increase, possibly explained by stimulation of drainage vessels growth. Both implants showed excellent biocompatibility. The flat CI showed a slight tendency towards better overall performances.

Keywords  Deep sclerectomy - Rabbit - Collagen glaucoma drainage device - Glaucoma surgery

Financial support: Fonds National Suisse pour la Recherche Scientifique N° 32-64103.00.
Financial interest: the study was partly sponsored (implants) by STAAR surgical AG, Nidau, Switzerland.

Fulltext Preview

Image of the first page of the fulltext document